language

    Confirm

    Product

    Project Case Study: 5.6MW Solar Plant in High Snow, Uneven Terrain

    Release time:

    2026-04-15

     

    Project Case Study: 5.6MW Solar Plant in High‑Snow, Uneven Terrain

    GT2 Single‑Post Ground Steel Racking System | HQ Mount


     

    Project Overview

    LocationHigh‑snow region, uneven mountainous terrain 
    Capacity5.6 MW solar power plant
    SystemHQ Mount GT2 single‑post ground steel racking
    Post MaterialZAM coated steel (S350GD) structure
    Upper Mounting StructureSteel solar mounting rails
    Solar FoundationRamming piles (adjustable for uneven ground)
    Design StandardsEN1991 (Eurocode) with site‑specific snow/wind loads
    Completion Year2026


     

    Challenge

    The site presented two major difficulties:


     

    • Heavy snow loads – required a robust structural design without over‑engineering
    • Uneven, sloped terrain – traditional two‑post systems would have required extensive ground leveling and hundreds of additional foundations


     

    The customer needed a solution that could adapt to varying pile heights while keeping installation fast and cost‑effective.


     

    Solution: HQ Mount GT2 Single‑Post System

    Single post per m solar panel array – each array uses only one foundation, dramatically reducing earthwork and pile installation time


     

    • Adjustable solar anchor pile – multiple holes in the post allow height adjustment without rework, plus optional extra adjustable components for extreme variations
    • Custom engineering – our in‑house team calculated local snow loads (over 2.5 kN/m²) and designed the structure to meet Eurocode safety margins
    • Factory pre‑assembly test – a full mock‑up was built at our facility to ensure all parts fit perfectly before shipment
    • Fast‑installation clamps – patented solar mounting rail and panel fixing clamps eliminated on‑site drilling


     

     

    Results & Customer Feedback


     

    • Installation time: Approximately 35% faster than a comparable two‑post system
    • Foundation cost: Reduced by nearly 40% (one pile per array vs. two)
    • Structural integrity: Passed all post‑installation load tests
    • Customer satisfaction: “Will use GT2 again for future projects in difficult terrain.”


     


     

    Why GT2 is Ideal for High‑Snow & Uneven Terrain


     

    • Fewer foundations – less digging, less concrete, less time
    • Height flexibility – each post can be adjusted independently to match ground slope
    • ZAM steel durability – 2‑6x better corrosion resistance than standard galvanization (SGS 4000H tested)
    • Engineered for heavy loads – custom calculations ensure safety without over‑specification
    • Pre‑tested delivery – no surprises on site


     


     

    Have a challenging site? Let’s talk.

    Our engineering team will design a GT2 system tailored to your local snow/wind loads and ground conditions.